Equipment settings:

Pressure F.S.
Power supply
Tube size
Kind of gas
Optionals


Interior exhaust valve

Interior exhaust valve to discharge the air present in the piece at the end of the test. The time of this phase can be set in the menu TST of the instrument.


Pneumatic filling fast

Pneumatic circuit with component mounting high flow to speed up the filling phase for large test volumes. The filling speed is 4 times higher for an instrument with standard pneumatic. Includes precision pressure regulator.


Kit sniffer Hydrogen H2

Includes internal pneumatic filling branch hydrogen and sniffer manual for position detection loss.


Frontal precision pressure regulator

Application of a mechanical regulator at very high precision: it can regulate pressure test with better accuracy and stability. Recommended for low pressures.


Pneumatic module of remote measurements

Based on Micro Electro Valves is a Pneumatic Module external to the measure equipment and aimed to minimize parasite volumes, increasing test sensibility and speed on small sizes of volume.


Electronic pressure Regulator

Application of an Electronic pressure regulator at very high precision for the automatic pressure setting; recommended where it is necessary a very high test precision or where it is necessary to change often test pressures. This option provides the installation of an internal expansion board in addition to the piezoelectric regulator and a dedicated pneumatic circuit.


Auto zero primary pressure circuit

It allows to make a phase of auto calibration of Zero drift of pressure


Positive test and negative test

Application of a pneumatic branch and of negative gage pressure measure, besides the conventional positive measure of scale. It is possible to set in the menu TST the desired pressure (positive or negative) and automatically the instrument will proceed to the filling with positive or negative pressure, based on the set value.


Pre-Filling

By the application of two mechanical manual regulators or by an electronic pressure regulator, it allows to perform the Filling Step with two or more pressures differents among them in order to reduce elastic and thermal phenomenons of the piece under test, reducing the time of Adjustement phase.


Waiting Primary pressure reading

It allows to display the direct pressure, besides in TEST steps also during Waiting and Stand By Step


Secondary Output of Waste (third result)

Particularly used on foundry pieces, it allows to add to the normal Good Waste threshold also a non-recoverable waste threshold (for Foundries: threshold of maximum chemical potting).


Leak Analog Output

Analog Output 0-10 V on AUX2 connector that repeats the loss detected in auto scale with the programmed loss.


I/O 24 Vdc expansion signal card

Expansion with 8 outputs (24 Vdc source type, max 2 A, opto isolated, completely safe) and 4 24 Vdc input Opto type.


Bi-manual logic Start Input

It accepts Start cycle by two separate Start signals (instead of only one) adhering to the regulations for bi-manual command EN 574. ATTENTION: Unless different annotations contained in each instrument handbooks, this sequence means to make safer the instrument utilization for single use and it cannot in any case be intended as a safe element for other parts handling (ex: presses, control cycles, etc...) connected to them.


Ethernet plug/TCP-IP

Ethernet connector for PC network connexion. It enables autonomous functions of connection TCP-IP and functions of direct connection to internet network with configurable IP.


Active USB port

USB port of Host type for the connection of a key storage for test results and for the copy of test parameters from an instrument to another one.


WI-FI connection

WI-FI connection 802.11 g for wireless connection of the instrument to PC.


Radio remote control selection Kit

4 channels Radio remote for instrument remote management. Frequency 433,92 MHz; 20m-100 run in open space. T


High resolution measure

By the application of superior components and transducers , a metrologic resolution of the measure of 1.000.000 points is guaranteed.


Capacitance meter for piece volume measure

Application of a volumetric capacity meter designed to determine automatically the cavity volume of the piece under Test. Besides it allows to make volume Tests with waste generation.


Double branches of pre-regulated pressures

Double branches of automatic pre-regulated pressures. By the application of two manual mechanical regulators, it is possible to change two pressures different among them.


Triple branches of pre-regulated pressures.

Triple branches of automatic pre-regulated pressures. By the application of three mechanical manual regulators it is possible to change automatically three pressures different among them.


Indirect measure

Indirect flow measure. This accessory is needed for under pressure flow tester.