Optionals
StaubliĀ© fittings for the connection to the front panel of calibrated leaks Leak_ID or of third parties, by StaubliĀ® hermetic fitting.
Application of a mechanical regulator at very high precision: it can regulate pressure test with better accuracy and stability. Recommended for low pressures.
Auto zero primary pressure circuit
It allows to make a phase of auto calibration of Zero drift of pressure
Pre-Filling
By the application of two mechanical manual regulators or by an electronic pressure regulator, it allows to perform the Filling Step with two or more pressures differents among them in order to reduce elastic and thermal phenomenons of the piece under test, reducing the time of Adjustement phase.
Waiting Primary pressure reading
It allows to display the direct pressure, besides in TEST steps also during Waiting and Stand By Step
Secondary Output of Waste (third result)
Particularly used on foundry pieces, it allows to add to the normal Good Waste threshold also a non-recoverable waste threshold (for Foundries: threshold of maximum chemical potting).
Leak Analog Output
Analog Output 0-10 V on AUX2 connector that repeats the loss detected in auto scale with the programmed loss.
Expansion with 8 outputs (24 Vdc source type, max 2 A, opto isolated, completely safe) and 4 24 Vdc input Opto type.
Bi-manual logic Start Input
It accepts Start cycle by two separate Start signals (instead of only one) adhering to the regulations for bi-manual command EN 574. ATTENTION: Unless different annotations contained in each instrument handbooks, this sequence means to make safer the instrument utilization for single use and it cannot in any case be intended as a safe element for other parts handling (ex: presses, control cycles, etc...) connected to them.
Ethernet connector for PC network connexion. It enables autonomous functions of connection TCP-IP and functions of direct connection to internet network with configurable IP.
USB port of Host type for the connection of a key storage for test results and for the copy of test parameters from an instrument to another one.
WI-FI connection 802.11 g for wireless connection of the instrument to PC.
Radio remote control selection Kit
4 channels Radio remote for instrument remote management. Frequency 433,92 MHz; 20m-100 run in open space. T
High resolution measure
By the application of superior components and transducers , a metrologic resolution of the measure of 1.000.000 points is guaranteed.
Indirect measure
Indirect flow measure. This accessory is needed for under pressure flow tester.