T9710

High performance leak tester for micro-flows

ForTest_Air_Flow_Tester_High_Level.jpg

Leak measurement with flow sensor
Leak display in volumetric mode (cc/h or cc/min) with a classic leak testing tool is restricted by setting the volume of the piece being tested which, using mathematical algorithms, allows conversion of the pressure decay in volumetric decay.
To release this system from restrictions, the flow leak tester T9710 was designed which, using one solid-state and one pressure sensor, displays the leaks detected directly in volumetric mode, with no need to set the volume being tested.
This characteristic makes it extremely versatile in the event of large volume variables being tested, and particularly intuitive in the analysis of test cycle progression.
 

     
Solid-state sensor Direct display of the volumetric leak Amplified test progression analysis capacity
 
Advanced interface.
For us, the T9000 series is the most technologically forward of measurement systems, equipped with an advanced interface, useful for analysis and research during the prototyping or pre-series phase, as well as for production line testing.
The big, 7” colour display set in a capacitive glass panel allows total interaction with the internal menus and the main screen. The "smart" testing archive contains daily and monthly analysis functions and those specifically for each test program, to keep the level of quality of your products under control.
 
     
7” full touch screen display Advanced analysis capacity "Smart" testing archive


Limitless connectivity.
The new T9710 equipment includes ports for the USB slave, RS232, RS485, Can bus and TTY. Assembly may also include an optional Ethernet port and a 26-pole connector with 4 inputs and 8 outputs, which are completely programmable, for interfacing with the external valves, safety barriers, switches, etc...
The front panel has a master USB port assembled on it for connection to a USB key to save the tests conducted, backup/restore parameters and upgrade tool firmware.
The connection to thermal printers, barcode/data-matrix readers and markers takes place automatically using an internal menu.

 
       
Usb key High power outputs RS232, RS485, Can, TTY Ethernet and auxiliary connector


Hybrid functioning.
The particular operation of the T9710 consists of continuous injection of test air, unlike a classic leak testing system, and directly measures the leak flow, which varies from a few cc/min to various hundredths, based on the application.
This system makes the tool suitable for measuring leaks which go beyond the classic leak testing scales, but which are not close to the normal flow test values, which normally arise to measure thousands of cc/min of leaking; this is why the nature of the T9710 is a hybrid between to technologies.
Measurement resolution starts with 0.1 cc/h based at the bottom of the scale, varying from 50 to 1,000 cc/min, with maximum pressure of 1 bar.
 
     
Continuous air injection Measurement up to 1,000 cc/min Resolution starting from 0.1 cc/h

Made to measure pneumatic section.
To avoid overheating due to long activation times of the filling circuit, we have designed particular, high capacity pneumatic valves, which not only work in hot temperatures, but also quickly fill the piece being tested, making the T9710 also suitable for testing on parts with significant volumes.
All of the above, while maintaining ForTest's historic reliability.
 
     
Heat-proof pneumatic valves High filling speed No periodic maintenance

Model 0-0,5bar 0,5-6 bar 0-200 cc/min 0-500 cc/min 0-1000 cc/min
Flow accuracy 1 - - 1% RDG+0,1%FS 1% RDG+0,2%FS 1% RDG+0,2%FS
Flow measurement range 1 - - 0-FS 0-FS 0-FS
Flow resolution - - 0,01 cc/min 0,1 cc/min 0,5 cc/min
Filling pressure accuracy 0,5%FS 0,5%FS - - -
Filling pressure measurement range 0-FS 0-FS - - -
Filling pressure resolution 0,01 mbar 0,1 mbar - - -
Leak measurement accuracy in cc/’ - - - - -
Leak measurement range in cc/’ - - - - -
Leak measurement resolution in cc/’ - - - - -
Volume measurement accuracy in cc/’ - - - - -
Volume measurement range in cc/’ - - - - -
Volume measurement resolution in cc/’ - - - - -
Unit of measurement mbar, bar, psi, mmHg, mmH2O, Pa, HPa, cc/min, cc/h, l/h, l/min.
Dimensions 300x160x350 mm
Weight 10 kg
Display dimensions 800x480 pixel
Working temperature range 5-40 °C
Port RS232 2
Port RS485 1
“Master” USB port 1
“Slave” USB port 1
Ethernet port Optional
I/O signals Start, Stop, Filling, Test, Good, Reject, 4BCD
Auxiliary I/O signals (optional) 8 output programmable, 4 input programmable, 4BCD
Number of programs 300
Test archive memory Advanced
Lock with password Yes
Program name Yes, 16 characters
Note The resolution to be considered for accuracy is always 1 Pa.

Reference Normatives: EN 61010-1, EN61326-1 / EN61326/A1, EN61000-3-2 / EN61000-3-2/A14, EN61000-3-3 / EN61000-3-3/A1, EN61000-4-2 / EN61000-4-2/A1, EN61000-4-3 / EN61000-4-3/A1 / EN61000-4-3/A2, EN61000-4-4, EN61000-4-5, EN61000-4-11, EN1779
 
  • The resolution for uncertainty calculation is 1 Pa up to 10 bar.
  • The flow measurement of the flow meters is of mass type and referred to the reference condition of 0°C - 1013,25mbar.
  • Flow measurement of leak test equipment is volumetric.
  • Accuracy data are referred to and guaranteed under laboratory calibration conditions.
  • The accuracy of the flow measurement is referred up to 2 bar, for higher pressures variations are possible depending on the characteristics of the model.
  • For measurement scales greater than the limits indicated, the accuracy will be specified in the offer phase.

1: can change according to the scale of the Pressure

  • External exhaust solenoid with protection filter
  • External start button
  • External start/abort pushbutton
  • External pushbutton 4 programs selection
  • Start pedal
  • Barcode reader
  • Adhesive label for printer 4500pcs
  • Aux signals extension cable
  • Venturi Vacuum generator
  • Air filter
  • Staubli male connector
  • Precision micrometer nozzle
  • Micrometer nozzle
  • M series manager software
  • TTY
  • Serial protocol
  • PC serial cable owner ---> M Series
  • External temperature probe
  • Thermal printer with peel-off
  • Thermal printer without peel
  • Adapter cable AUX M Series ---> ET Series
  • Remote Start / Abort / Good / Reject
  • Software "Data Manager"
  • Air filter 5 micron

  • Frontal connector for Staubli calibrated leak
  • Frontal precision pressure regulator
  • Auto zero primary pressure circuit
  • Pre-Filling
  • Waiting Primary pressure reading
  • Secondary Output of Waste (third result)
  • Leak Analog Output
  • I/O 24 Vdc expansion signal card
  • Bi-manual logic Start Input
  • Ethernet plug/TCP-IP
  • Active USB port
  • WI-FI connection
  • Radio remote control selection Kit
  • High resolution measure - (STANDARD)
  • Indirect measure

Message Sent

Message not sent

Message not sent correctly. Check out your connection