High speed for small volumes.
T6961 was designed for ultra fast testing of small parts (pneumatic valves, pressure switches, micro-valves in plastic for medical use, needles, catheters, biomedical components etc.).
This characteristics makes it suitable for use on high production automatic machines, allow assembly of the pneumatic unit behind the part being tested, for maximum reduction of the parasite volume. The differential measurement technology also allows detection of extremely low leaks (example medicinal valves: 10 cc/h at 2 bar in 0.1 s. of testing).
Test time of a few tenths of a second | Remote pneumatic unit | Ideal for small pieces (maximum 20cc) |
Usb key | High power outputs | RS232, RS485, Can |
With the external pneumatic module it will be possible to significantly reduce the volume under test, placing the pneumatic unit close to the part to be tested and therefore guaranteeing a cycle of tests with extremely reduced times. However, it is also available in a "stand alone" version with internal pneumatics. Thanks to the small dimensions of the instrument, the construction of multipoint counters is simplified. For a volume of 3 cc, it will only take 0.1 seconds to perform a tight and repeatable leak test, detecting a loss of 10 cc/h at 2 bar. It can be used in all those sectors where there are small parts with reduced cycle times (valves for tires, pressure switches, micro-valves in medical plastic, needles, catheters, butterfly needles, biomedical components, etc.). The instrument is available in scales from 0.5 to 10 bar. Thanks to the new software and hardware features, the T6961 boasts a resolution of up to 1 Pa.
Differential Technology | Window Centering Technology | Resolution of 1 Pa up to 10 bar |
Ideal for volumes up to 20cc | Remote external unit | Differential technology |
User-friendly interface | Easy to clean | 360° use |
Model | 0-0,2 bar | 0-0,5 bar | 0-1 bar | 0-2 bar | 0-3 bar | 0-6 bar | 0-10 bar | |
Accuracy Dp | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT | 1% RDG+3DGT | |
Range of measurements Dp | 0-65 mbar | 0-65 mbar | 0-65 mbar | 0-65 mbar | 0-65 mbar | 0-65 mbar | 0-65 mbar | |
Resolution Dp | 0,01 mbar | 0,01 mbar | 0,01 mbar | 0,01 mbar | 0,01 mbar | 0,01 mbar | 0,01 mbar | |
Direct pressure accuracy | 1,0%FS | 1,0%FS | 1,0%FS | 1,0%FS | 1,0%FS | 1,0%FS | 1,0%FS | |
Direct pressure measurement range | 0-FS | 0-FS | 0-FS | 0-FS | 0-FS | 0-FS | 0-FS | |
Direct pressure resolution | 0,01 mbar | 0,01 mbar | 0,1 mbar | 0,1 mbar | 0,1 mbar | 0,1 mbar | 1 mbar | |
Accuracy measuring loss in cc/’ | 1%RDG+0,01cc/min | 1%RDG+0,01cc/min | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min | 1%RDG+0,03cc/min | |
Measurement range in cc/’ | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min | 0-10 cc/min | |
Measured measurement resolution in cc/’ | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min | 0,01 cc/min | |
Measure unit | mbar, bar, psi, mmHg, mmH2O, Pa, HPa, cc/min, cc/h, pressure/s. | |||||||
Dimensions equipment | L:180 H:160 l:200 mm | |||||||
Dimensions remote group | L:45 H:130 l:85 mm | |||||||
Weight | 5 kg | |||||||
Display size | 320 x 240pixel | |||||||
Operating temperature range | 5-40 °C | |||||||
RS232 ports | 2 | |||||||
RS485 ports | 1 | |||||||
“master” USB port | 1 | |||||||
“slave” USB port | 1 | |||||||
Ethernet port | Optional | |||||||
I/O signals | Start, Stop, Filling, Test, Good, Reject, 4BCD | |||||||
Auxiliary I/O signals (optional) | - | |||||||
Number of programs | 100 | |||||||
Test archive memory | Standard | |||||||
Password block | Yes | |||||||
Program name | No | |||||||
Note | The resolution to be considered for accuracy is always 1 Pa. Reference Normatives: EN 61010-1, EN61326-1 / EN61326/A1, EN61000-3-2 / EN61000-3-2/A14, EN61000-3-3 / EN61000-3-3/A1, EN61000-4-2 / EN61000-4-2/A1, EN61000-4-3 / EN61000-4-3/A1 / EN61000-4-3/A2, EN61000-4-4, EN61000-4-5, EN61000-4-11, EN1779
|